T12 Fluorescent Ballasts for Rail & Bus Applications
T12 FLUORESCENT BALLAST 76 VDC MAX 2x40W
T12 FLUORESCENT BALLAST 37 VDC MAX 2x40W
MODEL NUMBER | PART #400-200-076(P) TYPE 2XT12B7640 |
TYPE | T12 FLUORESCENT BALLAST 76 VDC MAX 2x40W |
Fluorescent Lamps | 2x Rapid Start 4 pin F15T12…F40T12 |
Ignition Type | 0.8sec Preheat |
Nominal Input Voltage | 76 VDC |
Input Voltage Range | 55….95 VDC |
Current Draw at Nominal Voltage | Max 1.5A with 2x40W Load |
Current Draw in Fault Shutdown Mode | < 50mA at 76 VDC |
Starting Frequency | 112kHz |
Operating (Output) Frequency | 50Khz |
Operating Temperature Range | -20degC….70degC |
Efficiency | >80% |
MTBF | >250 000 hrs |
External Connections | Mate’n’lock Connectors |
Circuit Board Material | FR4 |
Enclosure | Aluminum |
Outside Dimensions | L7.7”(8.3” between mt. holes), W2.25”, H1.65” |
Insulation Resistance | >100Mohm 500 VDC |
Dielectric Rigidity (Input/Output to Frame) | 1000Vac 60Hz for 1min |
Protection Against | Input Polarity Reversal Lamp Failure (low power shutdown) Lamp Removal (low power shutdown) Output Short (low power shutdown) Internal Short (built in fuse) Transient Protection Thermal Protection |
Features | Fast Preheat Ignition Independent Lamp Operation Standby Control Line Auto Restart (after brownout or relamping) Shutdown Recovery (by relamping or power cycling) |
Standards Conformity | IEC60571, IEC61000-4-2/3/4/6, EN55011, EN55022, CISPR11, CISPR15, FCC Part 18 non-consumer |
T12 FLUORESCENT BALLAST 37 VDC MAX 2x40W
MODEL NUMBER | PART #400-200-0370 TYPE 2XT12B3740 |
TYPE | T12 FLUORESCENT BALLAST 37 VDC MAX 2x40W |
Fluorescent Lamps | 2x Rapid Start 4 pin F15T12…F40T12 |
Ignition Type | 0.8sec Preheat |
Nominal Input Voltage | 37 VDC |
Input Voltage Range | 24…45 VDC |
Current Draw at Nominal Voltage | Max 2.5A with 2x40W Load |
Current Draw in Fault Shutdown Mode | < 50mA at 37 VDC |
Starting Frequency | 112kHz |
Operating (Output) Frequency | 50Khz |
Operating Temperature Range | -20degC….70degC |
Efficiency | >80% |
MTBF | >250 000 hrs |
External Connections | Mate’n’lock Connectors |
Circuit Board Material | FR4 |
Enclosure | Aluminum |
Max Outside Dimensions | L7.6”(8.3” between mt. holes), W2.25”, H1.65” |
Insulation Resistance | >100Mohm 500 VDC |
Dielectric Rigidity (Input/Output to Frame) | 1000 VAC 60Hz for 1min |
Protection Against | Input Polarity Reversal Lamp Failure (low power shutdown) Lamp Removal (low power shutdown) Output Short (low power shutdown) Internal Short (built in fuse) Transient protection Thermal protection |
Features | Fast Preheat Ignition Independent Lamp Operation Standby Control Line Auto Restart (after brownout or relamping) Shutdown Recovery (by relamping or power cycling) |
Standards Compliance | IEC60571, IEC61000-4-2/3/4/6, EN55011, EN55022, CISPR11, CISPR15, FCC Part 18 non-consumer |